Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Arq. bras. oftalmol ; 86(6): e2021, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520196

ABSTRACT

ABSTRACT Purpose: The purpose of this study was to compare the white-to-white distance measurements of two devices (IOL Master 500 and Atlas corneal topographer) commonly used in clinical practice to determine if they were interchangeable. Providing information on instrument interchangeability could eliminate several unnecessary tests and consequently reduce the economic burden for the patient and society. Methods: In this prospective, comparative case series, the white-to-white distance was measured by independent examiners using the Atlas topographer (Carl Zeiss Meditec) and the IOL Master 500 (Carl Zeiss Meditec). One eye each of 184 patients was tested. Statistical analyses were performed using a paired t-test, Pearson correlation analysis, and Bland-Altman analysis to compare the measurement methods. Results: The mean white-to-white distance measurements with the Atlas topographer and the IOL Master 500 were 12.20 ± 0.44 mm and 12.12 ± 0.41 mm, respectively (p<0.001). The mean white-to-white difference between the two devices was 0.07 mm (95% confidence interval of mean difference: 0.04-0.11 mm). The Pearson correlation coefficient between the two devices was 0.85 (p<0.0001). The 95% limits of agreement between the two devices were -0.38 mm to 0.53 mm. Conclusions: The Atlas topographer and IOL Master 500 can be used interchangeably with respect to white-to-white distance measurements, as the range of differences is unlikely to affect clinical practice and decision making.


RESUMO Objetivo: O objetivo deste estudo é comparar as medições de diâmetro corneano de dois dispositivos normalmente utilizados na prática clínica (IOL Master 500 e Atlas topógrafo corneal) para ver se são permutáveis. O fornecimento de informações sobre a permutabilidade de instrumentos poderia eliminar vários testes desnecessários e, consequentemente, reduzir a carga econômica para o paciente e para a sociedade. Métodos: Nesta série de casos prospectivos e comparativos, a distância do diâmetro corneano foi medida por examinadores independentes utilizando o Topógrafo Atlas (Carl Zeiss Meditec) e o IOL Master 500 (Carl Zeiss Meditec), em um olho de 184 pacientes. A análise estatística foi realizada utilizando o teste t pareado, a correlação Pearson e a análise Bland-Altman para comparar os métodos de medição. Resultados: As medições médias da distância do diâmetro corneano com o topógrafo Atlas e o IOL Master 500 foram de 12,20 ± 0,44 mm e 12,12 ± 0,41 mm, respectivamente (p<0,001). A diferença média de WTW entre os dois dispositivos foi de 0,07 mm (intervalo de confiança de 95% da diferença média: 0,04 - 0,11 mm). O coeficiente de correlação Pearson entre os dois dispositivos foi de 0,85, p<0,0001. Os limites de concordância de 95% entre os dois dispositivos foram de -0,38 mm a 0,53 mm. Conclusões: O Atlas topographer e o IOL Master 500 podem ser utilizados permutavelmente em relação à medição do diâmetro corneano, uma vez que a gama de diferenças encontradas é pouco susceptível de afetar a prática clínica e a tomada de decisões.

2.
Arq. bras. oftalmol ; 84(4): 316-323, July-Aug. 2021. tab, graf
Article in English | LILACS | ID: biblio-1285290

ABSTRACT

ABSTRACT Purpose: The purpose of this study was to analyze the safety of primary intraocular lens implantation in a large number of eyes in children aged <24 months. Methods: The medical records of patients aged 5-24 months, who underwent primary intraocular lens implantation in the capsular bag, were reviewed. A foldable three-piece acrylic intraocular lens was implanted by the same surgeon using a single surgical technique. Patients who had <1 year of follow-up after the surgery were excluded. The main outcome measurements included visual acuity, myopic shift, follow-up complications, and additional surgeries. Results: Sixty-eight patients (93 eyes) were analyzed. The mean age of the patients at the time of surgery was 15.06 ± 6.19 months (range: 5-24 months), and the spherical equivalent 1 month after surgery was 3.62 ± 2.32 D. After 5.67 ± 3.10 years, the spherical equivalent was -0.09 ± 3.22 D, and the corrected distance visual acuity was 0.33 ± 0.33 and 0.64 ± 0.43 logMAR in bilateral and unilateral cases, respectively (p=0.000). The highest myopic shift was observed in infants who underwent surgery at ages 5 and 6 months. The most frequent complications included visual axis opacification and corectopia. Glaucoma and retinal detachment were not reported. Conclusion: Primary in-the-bag intraocular lens implantation in children aged 5-24 months is safe, and is associated with low rates of adverse events and additional surgery.


RESUMO Objetivo: O objetivo deste estudo foi analisar a segurança do implante de lente intraocular primária em um grande número de olhos em crianças <24 meses. Métodos: Foram revisados os prontuários de pacientes com idade entre 5-24 meses, submetidos a implante primário de lente intraocular no saco capsular. Uma lente intraocular acrílica de três peças dobrável foi implantada pelo mesmo cirurgião usando uma única técnica cirúrgica. Pacientes que tiveram <1 ano de acompanhamento após a cirurgia foram excluídos. Os principais resultados incluíram medidas de acuidade visual, mudança miópica, complicações pós operatórias e cirurgias adicionais. Resultados: Foram analisados 68 pacientes (93 olhos). A média de idade dos pacientes no momento da cirurgia foi de 15,06 ± 6,19 (5 a 24) meses, e o equivalente esférico 1 mês após a cirurgia foi de 3,62 ± 2,32 D. Após 5,67 ± 3,10 anos, o equivalente esférico foi de -0,09 ± 3,22 D, e a acuidade visual corrigida à distância foi de 0,33 ± 0,33 e 0,64 ± 0,43 logMAR em casos bilaterais e casos unilaterais, respectivamente (p=0,000). A maior mudança míopica foi observado em bebês submetidos à cirurgia aos 5 e 6 meses de idade. As complicações mais frequentes incluíram opacificação do eixo visual e corectopia. Glaucoma e descolamento de retina não foram relatados. Conclusão: O implante primário de lente intraocular no saco capsular em crianças de 5-24 meses é seguro e está associado à baixas taxas de eventos adversos e cirurgias adicional.


Subject(s)
Child , Child, Preschool , Humans , Infant , Cataract Extraction , Lenses, Intraocular , Postoperative Complications , Retrospective Studies , Follow-Up Studies , Lens Implantation, Intraocular/adverse effects
3.
Arq. bras. oftalmol ; 84(3): 271-274, May-June 2021. graf
Article in English | LILACS | ID: biblio-1248964

ABSTRACT

ABSTRACT This study aimed to analyze the anterior lens capsule specimens from both eyes of a patient with systemic sclerosis and compare them to the eyes of a control patient. No significant differences between systemic sclerosis and control eyes were observed in the results from the hematoxylin-eosin and picrosirius staining. In the samples obtained from both systemic sclerosis and control eyes, there were expressions of caspase, a molecule expressed in cell death by apoptosis. Heparanase was overexpressed in the systemic sclerosis sample compared to the control sample. Therefore, the anterior lens capsule of the patient with systemic sclerosis is probably affected by the disease since it showed marked expression of heparanase 1.(AU)


RESUMO Analisamos as amostras das cápsulas anteriores do cristalino de uma paciente com esclerose sistêmica e comparamos com as de um paciente controle. Não foram observadas diferenças significativas entre esclerose sistêmica e controle nos resultados da coloração com hematoxilina-eosina e picrosirius. Nas amostras obtidas da esclerose sistêmica e do controle, obtivemos expressão de caspase, uma molécula expressa na morte celular por apoptose. A heparinase foi expressa de forma mais marcante na amostra de esclerose sistêmica quando comparada ao controle. Portanto, a cápsula anterior do cristalino da paciente com esclerose sistêmica provavelmente foi afetada pela doença, uma vez que mostrou expressão aumentada de heparinase 1.(AU)


Subject(s)
Humans , Scleroderma, Systemic/physiopathology , Heparin Lyase/administration & dosage , Hematoxylin , Lens Capsule, Crystalline/anatomy & histology
4.
Clinics ; 75: e1604, 2020. tab, graf
Article in English | LILACS | ID: biblio-1133462

ABSTRACT

OBJECTIVE: To compare the effects of hydrophobic and hydrophilic materials in square-edged acrylic intraocular lenses (IOLs) on the development of posterior capsule opacification (PCO) after pediatric cataract surgery. METHODS: Patients were randomly assigned to group 1 (hydrophobic acrylic square-edged IOLs; 13 eyes) or group 2 (hydrophilic acrylic square-edged IOLs; 13 eyes). The study evaluated PCO rates using Evaluation of Posterior Capsule Opacification (EPCO) 2000 software at one, three, six and 12 months postoperatively. Postoperative measurements also included corrected distance visual acuity (CDVA), neodymium:yttrium‐aluminum‐garnet (Nd:YAG) capsulotomy and postoperative complications other than PCO. RESULTS: Both groups had significant increases in PCO rates after one year. Comparison of the groups showed no significant differences in the EPCO scores at three (group 1, 0.007±0.016 vs group 2, 0.008±0.014; p=0.830), six (group 1, 0.062±0.103 vs group 2, 0.021±0.023; p=0.184), or twelve months postoperatively (group 1, 0.200±0.193 vs group 2, 0.192±0.138; p=0.902). We also found no significant group differences regarding the change (delta, Δ) in EPCO scores between three and six months (group 1, 0.055±0.09 vs group 2, 0.013±0.02; p=0.113) or between six and twelve months postoperatively (group 1, 0.139±0.14 vs group 2, 0.171±0.14; p=0.567). Twenty-three percent of patients required Nd:YAG capsulotomy at the twelve-month visit. CONCLUSIONS: No differences in PCO rates were found between hydrophobic and hydrophilic acrylic square-edged IOLs in children between five and twelve years of age at one year of follow-up.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Cataract , Capsule Opacification , Lenses, Intraocular , Postoperative Complications , Prosthesis Design , Acrylic Resins , Prospective Studies , Phacoemulsification , Lens Implantation, Intraocular
5.
Arq. bras. oftalmol ; 82(5): 377-380, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019430

ABSTRACT

ABSTRACT Purpose: To assess the frequency of corneal astigmatism before cataract surgery in a Brazilian sample. Methods: This clinic-based cross-sectional study was conducted at the Bonsucesso Federal Hospital, Rio de Janeiro, Brazil. Charts of patients who underwent cataract surgery over a two-year period were retrospectively reviewed, and preoperative keratometric measurements were collected and analyzed. Results: A total of 1707 eyes of 1045 patients were enrolled. The corneal astigmatism was less than 1.0 D in 971 eyes (56.9%), 1.0-1.99 D in 496 eyes (29.1%), 2.0-2.99 D in 157 eyes (9.2%), and more than 3.0 D in 83 eyes (4.9%). The mean corneal astigmatism was 0.92 ± (SD) 0.96 D (range 0 - 10.25 D). Conclusion: Over 40% of the patients undergoing cataract surgery enrolled in this study had more than 1.0 D of corneal astigmatism and may benefit from the use of toric intraocular lenses. These data can be useful for planning to make this technology available for patients.


RESUMO Objetivo: Avaliar a prevalência do astigmatismo corneano antes da cirurgia de catarata em pacientes brasileiros. Métodos: Este estudo transversal de base clínica foi realizado no Hospital Federal de Bonsucesso, Rio de Janeiro, Brasil. Os prontuários de pacientes submetidos à cirurgia de catarata durante um período de dois anos foram revisados retrospectivamente, e as medidas ceratométricas pré-operatórias foram coletadas e analisadas. Resultados: Um total de 1.707 olhos de 1045 pacientes foram incluídos. O astigmatismo corneano foi menor que 1,0 D em 971 olhos (56,9%), 1,0-1,99 D em 496 olhos (29,1%), 2,0-2,99 D em 157 olhos (9,2%) e mais de 3,0 D em 83 olhos (4,9%). A média do astigmatismo corneano foi de 0,92 ± (SD) 0,96 D (intervalo 0-10,25 D). Conclusão: Mais de 40% dos pacientes estudados submetidos à cirurgia de catarata incluídos neste estudo tinham mais de 1,0 D de astigmatismo corneano e podem se beneficiar do uso de lentes intraoculares tóricas. Esses dados podem ser úteis no planejar a disponibilização dessa tecnologia para os pacientes.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Astigmatism/epidemiology , Cataract/complications , Cataract Extraction , Corneal Diseases/epidemiology , Brazil/epidemiology , Prevalence , Cross-Sectional Studies , Retrospective Studies , Cornea/physiopathology , Hospitals, Public
6.
Clinics ; 74: e966, 2019. tab, graf
Article in English | LILACS | ID: biblio-1011924

ABSTRACT

OBJECTIVES: To compare long-term postoperative complications of pediatric cataract surgery with primary intraocular lens (IOL) implantation associated with posterior capsulotomy (PC) and anterior vitrectomy (AV) between patients treated with a corneal or pars plicata/pars plana approach. METHODS: Children who underwent cataract surgery with in-the-bag primary IOL implantation were divided into two groups according to PC and AV surgical approach: a corneal approach (group 1) and a pars plicata/pars plana approach (group 2). Only patients with a follow-up duration of more than two years were included. Long-term surgical outcomes were retrospectively reported. RESULTS: The mean follow-up period was 10.00±3.13 years. No cases of glaucoma or retinal detachment were reported. The mean age at surgery was 34.57±22.66 months. Forty-six children were included (27 eyes in group 1 and 29 eyes in group 2). The most frequent postoperative complication was corectopia, followed by visual axis opacification. Both complications occurred more frequently in group 1 (p<0.001). After cataract surgery, the rate of additional surgeries in group 1 was 51.9%, while in group 2, the rate was 27.6% (p=0.1132). CONCLUSION: The pars plicata/pars plana approach with PC and vitrectomy with primary in-the-bag IOL implantation for pediatric cataracts is a safe procedure.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Cataract/congenital , Cataract Extraction/methods , Lens Implantation, Intraocular/methods , Postoperative Complications , Vitrectomy , Cataract Extraction/adverse effects , Retrospective Studies , Follow-Up Studies , Lens Implantation, Intraocular/adverse effects , Posterior Capsulotomy
7.
Arq. bras. oftalmol ; 81(5): 433-436, Sept.-Oct. 2018. graf
Article in English | LILACS | ID: biblio-950486

ABSTRACT

ABSTRACT A patient with bilateral aniridia and progressive congenital cataract was treated at the age of 7 years through phacoaspiration with femtosecond laser capsulotomy, in-the-bag intraocular lens implantation, and pars plana vitrectomy (combined with posterior capsulotomy). The diameter of the planned anterior capsulotomy was 4.7 mm; however, due to elevated tension in the young capsular bag, the capsulotomy diameter increased (to around 6 mm) shortly after release of the tension by the laser. In addition, the patient had a very flat and small cornea, causing the formation of air bubbles in the curved laser interface. This was addressed by filling the gap by using a viscoelastic. A very similar situation was observed in both eyes. Use of the femtosecond laser facilitated a successful outcome in a complex congenital cataract case with a safe capsulotomy that ensured in-the-bag intraocular lens placement.


RESUMO Paciente com aniridia bilateral e catarata congê­nita progressiva foi tratado com a idade de 7 anos através de facoemulsificação com capsulotomia anterior por laser de femtosegundo, implante de lente intra-ocular e vitrectomia via pars plana (combinada com capsulotomia posterior). O diâmetro da capsulotomia anterior prevista foi de 4,7mm, porém, devido à elevada tensão do saco capsular jovem, o diâmetro da capsulotomia aumentou (para cerca de 6mm) logo após a liberação da tensão pelo laser. Além disso, o paciente tinha uma córnea muito plana e pequena, causando a formação de bolhas de ar na interface do laser. Isso foi resolvido preenchendo a lacuna usando um viscoelástico. Uma situação muito semelhante foi observada em ambos os olhos. O uso do laser de femtosegundo facilitou um resultado bem-sucedido em um caso complexo de catarata congênita com uma capsulotomia anterior segura que garantiu a colocação da lente intra-ocular dentro do saco capsular.


Subject(s)
Humans , Male , Child , Cataract/congenital , Aniridia/complications , Capsulorhexis/methods , Cataract/complications , Visual Acuity , Aniridia/surgery , Laser Therapy/methods
8.
Arq. bras. oftalmol ; 81(4): 348-353, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-950474

ABSTRACT

ABSTRACT Patients undergoing cataract surgery are generally elderly, and many take drugs with systemic effects. The surgeon must be aware of the risks of continuing or discontinuing such medications perioperatively. Antiplatelet drugs and anticoagulants, prescribed to reduce the incidence of thromboembolic events, are often used in this population. This paper aims to review the perioperative use of antiplatelet and anticoagulant drugs in the setting of cataract surgery. Topical or intracameral anesthesia is preferred over anesthesia injected with needles. Aspirin can be safely continued in patients undergoing cataract surgery. Warfarin has been extensively studied, and the risk of hemorrhage associated with cataract surgery is low if the international normalized ratio is in the therapeutic range. Only a few studies of direct oral anticoagulants are available, and therefore no definite recommendations regarding those agents can be made at this time. Anesthesia in cataract surgery carries a low risk, even for patients taking anticoagulant or antiplatelet drugs. The discontinuation of this class of drugs before cataract surgery may increase the risk of thromboembolism.


RESUMO Os pacientes submetidos à cirurgia de catarata são geralmente idosos e muitos deles usam drogas com efeitos sistêmicos. No entanto, o cirurgião deve estar ciente dos riscos em manter ou descontinuar medicamentos sistêmicos no pré-operatório da cirurgia de catarata, como os anticoagulantes e os antiplaquetários. Este artigo tem como objetivo revisar a classe de drogas antiplaquetárias e anticoagulantes e orientar o cirurgião de catarata. A classe de fármacos anticoagulantes e antiplaquetária reduz a incidência de eventos potencialmente tromboembólicos. A anestesia tópica ou intracameral nesses pacientes deve ser preferida em relação à anestesia com agulhas. Aspirina pode ser mantida com segurança nos pacientes submetidos à cirurgia de catarata. A varfarina foi amplamente estudada e os riscos na cirurgia de catarata são baixos, no entanto, o INR deve ser controlado. Mais estudos são necessários com anticoagulantes orais diretos. Anestesia na cirurgia de catarata tem baixo risco de complicações, mesmo em uso de anticoagulantes ou antiplaquetários sistêmicos. A descontinuação desta classe de medicamentos no pré-operatório da cirurgia de catarata pode aumentar os riscos sistêmicos tromboembólicos.


Subject(s)
Humans , Platelet Aggregation Inhibitors/administration & dosage , Cataract Extraction/methods , Anticoagulants/administration & dosage , Platelet Aggregation Inhibitors/adverse effects , Cataract Extraction/adverse effects , Risk Factors , Venous Thromboembolism/prevention & control , Intraoperative Period , Anticoagulants/adverse effects
9.
Arq. bras. oftalmol ; 80(4): 238-241, July-Aug. 2017. tab
Article in English | LILACS | ID: biblio-888125

ABSTRACT

ABSTRACT Purpose: To study the technique of eye drop instillation in glaucoma patients and identify independent factors that may influence their performance. Methods: In this cross-sectional study, 71 consecutive patients with glaucoma or ocular hypertension, self-administering topical anti-glaucoma medications for ≥6 months were evaluated. All patients instilled a tear substitute into the eye with the worst eyesight using the technique normally used at home. The following parameters were evaluated: age, number of years receiving treatment with ocular hypotensive eye drops, time spent to instill the first drop, number of drops instilled, correct location of the eye drops, contact of the bottle with the eye, closing of the eyelids or occlusion of the tear punctum, and asepsis of the hands. Results: The mean age of the patients was 66 ± 10.8 years, and patients were on ocular hypotensive drugs for 11.3 ± 7.3 (range, 2-35) years. Only 28% of the patients were able to correctly instill the eye drops (squeeze out 1 drop and instill it into the conjunctival sac without bottle tip contact). Touching the tip of the bottle to the globe or periocular tissue occurred in 62% of the patients. In 49% of the patients, the eye drops fell on the eyelids or cheek. Two or more drops were squeezed by 27% of the patients. Conclusions: The majority of glaucoma patients were unable to correctly instill eye drops. Age was an independent factor associated with eye drop instillation performance.


RESUMO Objetivo: Avaliar a técnica de instilação de colírio em portadores de glaucoma e identificar fatores independentes que pode influenciar o desempenho. Métodos: Neste estudo transversal 71 pacientes consecutivos com glaucoma ou hipertensão ocular que auto instilam seus colírios há pelo menos 6 meses, foram avaliados. Todos os pacientes instilaram um colírio lubrificante no olho de pior visão utilizando a mesma técnica de instilação de colírio que utilizam rotineiramente em casa. Foram avaliados parâmetros como: idade, número de anos em tratamento com colírios hipotensores oculares, tempo gasto para instilação da primeira gota, número de gotas instiladas, localização correta do colírio, contato do frasco com o olho, fechamento de pálpebras ou oclusão do ponto lacrimal e assepsia das mãos. Resultados: A idade média dos pacientes foi de 66 ± 10,8 anos. Os pacientes esta vam em tratamento com colírios hipotensores oculares por, em média, 11,3 ± 7,3 anos (variando de 2 a 35 anos). Apenas 28% dos pacientes foram capazes de instilar corretamente o colírio (instilação de 1 gota em saco conjuntival sem contato com a ponta do frasco). Contato da ponta do frasco com o olho ou tecido periocular ocorreu em 62% dos pacientes. Em 49% dos casos, o colírio caiu nas pálpebras ou fora do saco lacrimal na primeira tentativa. Duas ou mais gotas foram instiladas por 27% dos pacientes. Conclusão: A maioria dos pacientes com glaucoma é incapaz de instilar o colírio corretamente. A idade é um fator independente que influencia o desempenho da instilação de colírio.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Ophthalmic Solutions/administration & dosage , Glaucoma/drug therapy , Time Factors , Instillation, Drug , Visual Acuity , Ocular Hypertension/drug therapy , Patient Education as Topic , Cross-Sectional Studies , Age Factors , Patient Compliance , Intraocular Pressure/drug effects
11.
Rev. bras. oftalmol ; 76(2): 101-105, Mar.-Apr. 2017. graf
Article in Portuguese | LILACS | ID: biblio-899044

ABSTRACT

Resumo O objetivo deste artigo foi reunir estudos que reportam resultados disponíveis na literatura científica, considerando a previsibilidade, segurança, eficácia, e estabilidade das lentes intraoculares fácicas de câmara posterior. E relatar as complicações documentadas para estas lentes. A revisão criteriosa dos estudos publicados na literatura ate o momento revelam resultado satisfatórios quanto à eficácia, elevada previsibilidade, estabilidade e segurança do implante de lente intraocular de câmara posterior, para correção das miopia, hipermetropia e astigmatismo.


Abstract The objective of this article was to gather studies that report results available in the scientific literature, considering the predictability, safety, efficacy, and stability of posterior chamber phakic intraocular lenses. And report the documented complications for these lenses.


Subject(s)
Humans , Refractive Errors , Lens Implantation, Intraocular/methods , Refractive Surgical Procedures/methods , Phakic Intraocular Lenses , Postoperative Complications , Refraction, Ocular/physiology , Astigmatism/surgery , Treatment Outcome , Posterior Eye Segment/surgery , Hyperopia/surgery , Myopia/surgery
12.
Rev. bras. oftalmol ; 76(1): 43-49, Jan.-Feb. 2017. tab
Article in Portuguese | LILACS | ID: biblio-844067

ABSTRACT

RESUMO O objetivo desta revisão é de determinar as indicações e eficácia da cirurgia que promove novas ligações covalentes entre as fibras de colágeno da córnea, conhecida como Cross-Linking (CXL), assim como esclarecer seus objetivos. O ceratocone é uma doença ectasica da córnea, bilateral, assimétrica, que, principalmente, cursa com encurvamento e afinamentos progressivo, e se inicia em geral na segunda década de vida. O uso primário do CXL tem sido na interrupção da progressão do Ceratocone. Apesar do conhecido encurvamento no estroma da córnea ocorrer nesses pacientes, a fisiopatologia por trás do ceratocone ainda é desconhecida e parece ser multifatorial. Pela evidencia literária disponível até o momento, o CXL da córnea esta, portanto indicado nos pacientes com doença em progressão. Concluímos que existe evidencia suficiente para afirmar que o CXL da córnea é eficaz na estabilização da doença ectásica da cornea.


ABSTRACT The purpose of this review is to determine the indications and efficacy of the surgery that promotes new covalent bonds between the collagen fibers of the cornea, known as Cross-Linking (CXL), as well as to clarify its objectives. Keratoconus is a bilateral, asymmetric ectasic disease of the cornea that mainly courses with steepening and progressive thinning, and usually begins in the second decade of life. The primary use of CXL has been in discontinuing the progression of keratoconus. Although known corneal stromal remodeling occurs in these patients, the pathophysiology behind keratoconus is still unknown and appears to be multifactorial. By the literary evidence available to date, the CXL of the cornea is safely indicated in patients with progressing disease. We conclude that there is sufficient evidence to affirm that cornea CXL is effective in stabilizing corneal ectasic disease.


Subject(s)
Cornea/metabolism , Cornea/physiology , Cross-Linking Reagents , Keratoconus/drug therapy , Guidelines as Topic , Riboflavin/administration & dosage
14.
Rev. bras. oftalmol ; 74(6): 403-406, nov.-dez. 2015.
Article in English | LILACS | ID: lil-767084

ABSTRACT

RESUMO A mitomicina C teve seu uso profilático e terapêutico estabelecido, ao longo dos anos, para diminuir o haze depois da ablação superficial. A mitomicina C é segura e eficaz como uma terapia adjuvante aplicada após um procedimento primário de ceratectomia fotorrefrativa ou após um retratamento com ceratectomia fotorrefrativa após o laser in situ keratomileusis LASIK. A mitomicina age modulando a cicatrização após a cirurgia. Constitui-se num potente inibidor de mitose, bloqueia a ativação e a profliferação dos fibroblastos e a diferenciação dos miofibroblastos. Embora existam muitos estudos apontando a segurança da mitomicina nas doses ultilizadas, ainda persistem dúvidas quanto à segurança, a longo prazo, do uso da mitomicina. Quando as córneas são examinadas com microscópios confocal, após depleção inicial dos ceratócitos, a densidade celular parece retornar ao normal seis a 12 meses após o uso de mitomicina C . A maioria dos estudos clínicos não encontrou diferença significativa entre a densidade endotelial celular préoperatória e pós-operatória quando a mitomicina C 0.02% foi aplicada durante a cirurgia com um tempo de exposição de 2 minutos ou menos. Em aproximadamente 14 anos, a mitomicina C mostrou-se eficaz na prevenção e tratamento do haze corneano.


ABSTRACT Over the years, mitomycin C has been used by refractive surgeons to prophylactically decrease haze after surface ablation procedures and therapeutically in the treatment of preexisting haze. Development of mitomycin C treatments has had a significant role in the revival of surface ablation techniques. We reviewed the literature regarding mechanism of action of mitomycin C, its role in modulating wound healing after refractive surgery, and its safety and efficacy as adjuvant therapy applied after primary photorefractive keratectomy surgery or after photorefractive keratectomy re-treatment after laser in situ keratomileusis and other corneal surgeries and disorders. The drug is a potent mitotic inhibitor that effectively blocks keratocyte activation, proliferation, and myofibroblast differentiation. Many studies have suggested that mitomycin C is safe and effective in doses used by anterior surface surgeons, although there continue to be concerns regarding long-term safety. After initial depletion of anterior keratocytes, keratocyte density seems to return to normal 6 to12 months after the use of mitomycin C when corneas are examined with the confocal microscope. Most clinical studies found no difference between preoperative and postoperative corneal endothelial cell densities when mitomycin C 0.02% was applied during refractive surgery,with exposure time of 2 minutes or less. After approximately 14 years of use, mitomycin C has been found to be effective when used for prevention and treatment of corneal haze.


Subject(s)
Humans , Wound Healing/drug effects , Mitomycin/pharmacology , Photorefractive Keratectomy , Corneal Opacity/prevention & control , Keratomileusis, Laser In Situ , Myofibroblasts/drug effects , Cicatrix/enzymology , Mitomycin/administration & dosage , Chemotherapy, Adjuvant , Apoptosis/drug effects , Cornea/drug effects , Corneal Opacity/etiology , Corneal Stroma/drug effects , Cell Proliferation/drug effects , Enzyme Activation
15.
Arq. bras. oftalmol ; 78(3): 173-174, May-Jun/2015.
Article in English | LILACS | ID: lil-753013

ABSTRACT

ABSTRACT Purpose: To analyze the safety of warfarin therapy during cataract surgery under topical anesthesia. Methods: This was a prospective nonrandomized comparative study of 60 eyes of 60 patients treated with or without concurrent oral warfarin anticoagulant therapy, referred for cataract surgery under topical anesthesia. The sample included a treatment (n=30) and a control (n=30) group. Results: There were no records of intraoperative or postoperative intracameral bleeding complications in both the groups. At 1-month postoperative follow-up, 90.0% of patients presented spectacle-corrected visual acuity of at least 20/40. Conclusion: Cataract surgery by phacoemulsification with topical anesthesia can be successfully conducted without discontinuing warfarin. .


RESUMO Objetivo: Avaliar a segurança da cirurgia de catarata com anestesia tópica em pacientes em uso de varfarina. Métodos: Estudo comparativo não aleatorizado, prospectivo de 30 olhos de 30 indivíduos sob terapia anticoagulante por via oral com Varfarina que se submeteram à cirurgia de catarata com anestesia tópica. O grupo controle foi composto por 30 olhos de 30 pacientes, com indicação de cirurgia de catarata, que não faziam uso de terapia anticoagulante. Resultados: Não houve registro de complicações hemorrágicas intracamerais transoperatórias ou pós-operatórias em ambos os grupos. Na visita pós-operatória de 30 dias, 90,0% dos pacientes apresentavam acuidade visual corrigida por óculos de pelo menos 20/40. Conclusão: A cirurgia de catarata por facoemulsificação com anestesia tópica pode ser realizada com sucesso sem interrupção da terapia com varfarina. .


Subject(s)
Humans , Anticoagulants/administration & dosage , Cataract Extraction/methods , Warfarin/administration & dosage , Administration, Oral , Anesthesia, Local , Anesthetics, Local/administration & dosage , Cataract Extraction/adverse effects , Eye Hemorrhage/chemically induced , Follow-Up Studies , Intraoperative Period , International Normalized Ratio/methods , Lens Implantation, Intraocular , Prospective Studies , Postoperative Hemorrhage/chemically induced , Visual Acuity
17.
Arq. bras. oftalmol ; 77(6): 373-376, Nov-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-735795

ABSTRACT

Purpose: To evaluate whether implantation of an aspheric intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery and, therefore, changes on frequency-doubling technology (FDT) testing. Methods: The present prospective clinical study enrolled 25 patients with bilateral cataract (50 eyes), who randomly received either an aspheric (Akreos AO) or a spherical (Akreos Fit) IOL in one eye and the other IOL in the second eye. Assessment 12 months postoperatively included photopic and mesopic contrast sensitivity testing. Higher-order aberrations (HOAs) were computed. FDT testing was divided into four areas to evaluate the variation of the values at different points. The median values of the local pattern thresholds (median area contrast sensitivity [MACS]) obtained with that division were calculated. Results: The Akreos AO group obtained statistically significantly lower values of HOAs and spherical aberration compared with the Akreos Fit group. There was a statistically significant between-group difference in contrast sensitivity under mesopic conditions at all spatial frequencies. No statistically significant differences were observed in mean deviation and pattern standard deviation. The aspheric IOL exhibited higher MACS in all areas, although a statistically significant difference was reached only in the 20-degree field area (P=0.043). Conclusion: Aspheric IOLs significantly reduced spherical aberration and HOAs, improving mesopic contrast sensitivity. Although there was a trend toward slightly improved FDT in the aspheric IOL group, it was not statistically significant. .


Objetivo: Avaliar se o implante de uma lente intraocular (LIO) asférica reduz a aberração ocular (alta ordem e esférica), melhora a sensibilidade ao contraste e consequentemente, provoca mudanças nos valores da perimetria de frequência dupla (FDT ). Métodos: Trata-se de um estudo prospectivo envolvendo 25 pacientes com catarata bilateral (50 olhos) que foram randomizados para receberem uma LIO asférica (Akreos AO) em um olho e uma LIO esfércia (Akreos Fit) no olho contralateral. Com 12 meses de pós-operatório a sensibilidade ao contraste (condições fotópicas e mesópicas) e a aberração de alta ordem foram computados. A FDT foi dividida em 4 áreas para análise da variação dos valores em diferentes localizações. Os valores médios dos limiares locais (área média de sensibilidade ao contraste [MACS]) obtidos com essa divisão foram calculados. Resultados: O grupo da Akreos AO apresentou menores valores de aberração de alta ordem e aberração esférica. Houve diferença estatisticamente significativa na sensibilidade ao contraste em condições mesópicas em todas frequências. Não houve diferença estatística nos valores do mean deviation e pattern standard deviation da FDT. A LIO asférica apresentou maiores MACS em todas as áreas, embora diferença estatística foi encontrada apenas na área de 20 graus de campo visual (P=0,043). Conclusões: A lente asférica reduziu significativamente a quantidade de aberração de alta ordem e esférica, melhorando a sensibilidade ao contraste em condições mesópicas. Embora houve uma melhora nos valores da FDT no grupo da LIO asférica, essa diferença não foi estatisticamente significativa. .


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Cataract Extraction/methods , Lenses, Intraocular , Lens Implantation, Intraocular/methods , Aberrometry , Contrast Sensitivity , Cataract/pathology , Cataract/physiopathology , Organ Size , Prospective Studies , Prosthesis Design , Pupil/physiology , Reference Values , Refractive Errors/physiopathology , Statistics, Nonparametric , Treatment Outcome
18.
Rev. bras. oftalmol ; 73(4): 199-201, Jul-Aug/2014.
Article in English | LILACS | ID: lil-730586

ABSTRACT

Purpose: Evaluate the magnitude of cyclotorsion during cataract surgery in patients with indication for intraocular toric lenses comparing the results after peribulbar and after topical anesthesia. Methods: This prospective study comprised 112 eyes that underwent cataract surgery with implantation of toric intraocular lens by topical anesthesia or peribulbar block. We estimated how many degrees of cyclotorsion occurred after topical anesthesia and peribulbar block with the patient in supine position. A tag was performed in the position of 180 degrees of the right eye and zero degrees of the left eye, with the patient seated. Afterwards, it was requested a change to the supine position and then a new dial in 180 and zero degrees respectively from right and left eye were made. Results: The current study demonstrated that patients submitted to cataract surgery with implantation of toriclens under local anesthesia showed approximately 6.89 degrees of incyclotorsion (82 eyes) and 6.93 degrees of excyclotorsion (38 eyes) and a mean of cyclotorsion of 6.91 degrees. Patients undergoing peribulbar block showed 5.68 degrees of incyclotorsion (73 eyes) and 4.81 degrees of excyclotorsion (47 eyes) and a mean of cyclotorsion of 4.92 degrees. Conclusion: Through the study we can see that the movement of incyclotorsion in patients undergoing peribulbar anesthesia was lower when compared to topical anesthesia. This is relevant since the greater the incyclotorsion, the lower the predictability of the surgery and the lower the chance of obtaining excellent results in the final refractometric. .


Objetivo: Avaliar a magnitude da ciclotorção durante a cirurgia de catarata em pacientes com indicação de lentes intraoculares tóricas comparando os resultados após o bloqueio peribulbar e após a anestesia tópica. Métodos: Esse estudo prospectivo compreende 112 olhos que foram submetidos à cirurgia de catarata com implante de lente intraocular tórica por meio de anestesia tópica ou bloqueio peribulbar. Foram estimados quantos graus de ciclotorção ocorreu após a anestesia tópica e após o bloqueio peribulbar, com o paciente em posição supina.Foi realizada uma marcação na posição de 180 graus do olho direito e zero grau do olho esquerdo, com o paciente sentado, em seguida,houve uma mudançade posição para decúbito dorsal, sendo realizadas novas marcações em 180 e zero graus dos olhos direito e esquerdo, respectivamente. Resultados: O presente estudo demonstrou que pacientes submetidos à facoemulsificação com implante de lente tórica com anestesia tópica apresentaram aproximadamente 6.89 graus de inciclotorção (82 olhos) e 6,93 graus de exciclotorção (38 olhos) com uma média de ciclotorção de 6.91 graus. Já os pacientes submetidos à anestesia peribulbar apresentaram 5.68 graus de inciclotorção(73 olhos) e 4,81 graus de exciclotorção (47 olhos) com uma média de ciclotorção de 4,92. Conclusão: Através do estudo podemos observar que o movimento de inciclotorção em pacientes submetidos à anestesia peribulbar foi menor quando comparado ao da anestesia tópica. Isso se torna relevante uma vez que, quanto maior for a inciclotorção, menor a previsibilidade da cirurgia e menor a chance de obtenção de excelência nos resultados refratométricos finais. .


Subject(s)
Humans , Optical Rotation , Posture , Torsion Abnormality/diagnosis , Cataract Extraction , Supine Position , Visual Acuity , Prospective Studies , Administration, Topical , Cornea/physiology , Lens Implantation, Intraocular , Eye Movements , Patient Positioning , Intraoperative Complications , Anesthesia, Local , Nerve Block
19.
Arq. bras. oftalmol ; 77(4): 222-224, Jul-Aug/2014. graf
Article in English | LILACS | ID: lil-728663

ABSTRACT

Purpose: To evaluate the incidence of posterior capsule opacification (PCO) four years after the implantation of a hydrophilic acrylic intraocular lens (IOL). Methods: Fifty-eight randomly selected eyes from 58 patients were analyzed four years after phacoemulsification and Ioflex IOL implantation. The patients underwent an ophthalmic examination to detect PCO and a detailed medical history was obtained. The patients' charts were reviewed for their corrected distance visual acuity prior to the IOL implantation, as well as for one month postoperatively. The Student's t-test was used for statistical analysis. Results: The mean age of patients without PCO was 74.6 ± 9.5 years, compared to 70.3 ± 15 years in patients with PCO. Four years after surgery, 39 of the 58 eyes (67%) had detectable PCO and 24 eyes (41.3%) had decreased visual acuity (VA) due to PCO. These patients were referred for Nd:YAG laser capsulotomy. Three patients (5.1%) had decreased VA due to glaucoma, IOL opacification, or age-related macular degeneration. Twelve eyes (20.7%) presented mild PCO with unchanged VA. Systemic arterial hypertension was reported by 45% of the patients, and in 3.5% of these cases this was associated with diabetes mellitus. Conclusion: This study found the incidence of PCO to be 67% four years after phacoemulsification and Ioflex IOL implantation. .


Objetivo: Avaliar a incidência da opacificação da cápsula posterior com o implante de uma lente intraocular acrílica hidrofílica. Métodos: Cinquenta e oito olhos, de 58 pacientes, selecionados de forma aleatória, foram examinados 4 anos após a cirurgia de facoemulsificação com implante da lente intraocular Ioflex em uma campanha comunitária para pessoas carentes. Os pacientes foram submetidos ao exame oftalmológico a fim de detectar opacificação da cápsula posterior. Foi obtido histórico médico detalhado. A acuidade visual corrigida antes e 1 mês após a cirurgia foi obtida através de revisão em prontuário médico. O teste t de student foi utilizado para a análise estatística. Resultados: A idade média dos pacientes sem opacificação da cápsula posterior foi 74,6 ± 9,5 anos, e 70,3 ± 15 anos nos pacientes com opacificação da cápsula posterior. Após 4 anos da cirurgia, 39 olhos (67%) foram diagnosticados com opacificação da cápsula posterior, e 24 olhos (41,3%) tiveram redução da acuidade visual causada pela opacificação da cápsula posterior, sendo encaminhados para realização de capsulotomia com Nd:YAG laser. Três olhos (5,1%) tiveram redução da acuidade visual causada por glaucoma, opacificação da lente intraocular e degeneração macular relacionada á idade. Em outros 12 olhos (20,7%) que apresentaram opacificação da cápsula posterior, a acuidade visual ficou mantida. Dentre as doenças sistêmicas, a hipertensão arterial foi relatada por 45% da amostra avaliada e 3,5% referiram diabetes mellitus. Conclusão: O estudo encontrou incidência de 67% de opacificação da cápsula posterior na lente intraocular Ioflex 4 anos ...


Subject(s)
Aged , Female , Humans , Male , Acrylic Resins/adverse effects , Capsule Opacification/etiology , Cataract Extraction/adverse effects , Lens Implantation, Intraocular/adverse effects , Capsule Opacification/epidemiology , Follow-Up Studies , Incidence , Postoperative Complications , Visual Acuity
20.
Arq. bras. oftalmol ; 76(5): 282-287, set.-out. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-690605

ABSTRACT

OBJETIVO: determinar a prevalência de sinais e sintomas de doença da superfície ocular (OSD) em pacientes em uso crônico de hipotensores oculares tópicos. MÉTODOS: Neste estudo transversal, foram recrutados 40 pacientes consecutivos, provenientes do ambulatório de glaucoma de um hospital público localizado no Rio de Janeiro, Brasil. Os mesmos deveriam apresentar: idade maior ou igual a 18 anos, diagnóstico de hipertensão ocular ou glaucoma primário de ângulo aberto e deveriam estar em uso da mesma terapia hipotensora ocular há pelo menos seis meses. Foram considerados: sexo, idade, medicação utilizada e duração do tratamento. Todos os pacientes foram submetidos à avaliação da superfície ocular que incluiu: entrevista por meio do questionário Ocular Surface Disease Index® (OSDI®), tempo de rotura do filme lacrimal, biomicroscopia, avaliação da superfície ocular com fluoresceína e com rosa Bengala. RESULTADOS: A média de pontuação do OSDI® foi 24,6 ± 20,7. A maioria dos pacientes (67,5%) apresentou uma pontuação anormal no questionário do OSDI®. Em 25% dos pacientes, a pontuação foi compatível com sintomas leves, em 12,5% com sintomas moderados e em 30% com sintomas graves. Blefarite e ceratite ponteada foram diagnosticadas em 42,5% e 20% dos pacientes respectivamente. Instabilidade do filme lacrimal foi observada em 75% dos pacientes, enquanto que alteração da superfície ocular foi evidenciada pelo teste de rosa bengala em 35% dos pacientes. Foi encontrada correlação positiva (r=0,4) estatisticamente significativa (p=0,01) entre a pontuação do OSDI® e o tempo de duração do tratamento com hipotensores oculares tópicos. CONCLUSÃO: Pacientes em uso crônico de hipotensores oculares tópicos apresentam alta prevalência de sinais e sintomas de OSD. Existe correlação significativa entre a duração do tratamento e a gravidade dos sintomas de OSD.


PURPOSE: To determine the prevalence of signs and symptoms of ocular surface disease (OSD) in patients using topical intraocular pressure-lowering therapy. METHODS: In this cross-sectional study, 40 patients were consecutively recruited from the glaucoma clinic of a public hospital located in Rio de Janeiro, Brazil. Eligible patients were 18 years of age or older, with primary open-angle glaucoma or ocular hypertension and on the same topical ocular therapy for at least 6 months. The following data were considered: sex, age, medication history and number of years on topical intraocular pressure-lowering therapy. All patients underwent an evaluation of the ocular surface which included: an interview using the Ocular Surface Disease Index® (OSDI®) questionnaire, break-up time, biomicroscopy, fluorescein corneal staining and rose Bengal ocular surface staining. RESULTS: The mean OSDI® score was 24.6 ± 20.7. Most patients (67.5%) had an abnormal score on the OSDI® questionnaire. In 25% of patients, the score was consistent with mild symptoms, 12.5% ​​with moderate symptoms and 30% with severe symptoms. Blepharitis and punctate keratitis were diagnosed in 42.5% and 20% of patients respectively. Tear film instability was observed in 75% of patients and ocular surface staining with rose Bengal in 35%. A positive statistically significant correlation (r=0.4; p=0.01) was found between OSDI® scores and the duration of topical intraocular pressure-lowering therapy. CONCLUSION: Patients with primary open-angle glaucoma or ocular hypertension on topical intraocular pressure-lowering therapy have high prevalence of OSD. Longer duration since diagnosis is significantly correlated with worsening of OSD symptoms.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Antihypertensive Agents/therapeutic use , Intraocular Pressure/drug effects , Ocular Hypertension/drug therapy , Sulfonamides/therapeutic use , Thiophenes/therapeutic use , Timolol/therapeutic use , Blepharitis/diagnosis , Cross-Sectional Studies , Cornea/drug effects , Fluorescein , Glaucoma, Open-Angle/prevention & control , Keratitis/diagnosis , Lacrimal Apparatus Diseases/diagnosis , Microscopy, Acoustic/methods , Severity of Illness Index , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL